Results 1 - 9 of 20 (page 1 of 3)

Main image
12
Title
Baby hanging scale
Description

Trousers: 100% polyester, taffeta 190T PVC coated length 30cm, scale: capacity 25kg/100g, L27 x W17 x T4.5cm

Main image
6
Title
bistouri blade
Description

Sterile, size n° 24, made by carbon steel, each packed by sealed sterile rust-proof paper bag

Main image
1
Title
Dental chair
Description

Seat height: 500-600mmBackrest angle of inclination: 110~180℃Headrest distance of movement: 80mmHeadrest angle of rotation: ≥25°Operation Light(1pc)Instrument tray (1pc)Spittoon (1pc), not showing in the pictureKnapsackReplaceable cushions

Main image
11
Title
Disposable diaper
Description

Rectangular and white diaper, non-woven surface + velveteen polymer absorbent layer in the middle + PE water-proof layer backside, size 100 x 90 cm, each packed by sealed sterile PE bag

Main image
5
Title
Examination gloves
Description

Rubber latex, pre-powdered or powder-free, not sterile, available sizes: 6.5, 7, 7.5, 8

Main image
4
Title
Female condom
Description

Plain; Straight, with teat; Natural latex; Lubricated with silicon, oil, non toxic, Natural color, Length: 170/180; width: 55 mm (+/- 2mm); thickness: 0.075mm (+/-0.015mm); 3 years life time; Condom Standard: ISO25841:2011; Certifications: CE, CCC, ISO 9001; Compliant with WHO recommendation

Main image
10
Title
Flannelette diaper
Description

Rectangular and white, flannelette material, size 100 x 90cm finished, ends with seam, each packed by a plastic bag

Main image
2
Title
High frequency mobile X-ray Equipment
Description
Main image
3
Title
Infant incubator
Description

Gross Weight: Main body 80Kg/ Cabinet 35Kg General description: AC Power/ DC Power; Power 12V or 24V. Air-temp or skin-temp servo-controlled by micro-computer; double walls hood could prevent heat losing hoodprevent the influence to the incubator exterior heat resource; quite operation windows can reduce the disturbance to the baby during nursing with oxygen cylinder oxygen supply system touch switch panel with LED digital display, set-temp, skin-temp, real-temp, storage battery voltage are displayed separately; indicated electricity-offer mode; night light, luminescence design; seven self-checking alarms with audible visible; heating power rate indicates 0-100; shockproof adjustable stand with cylinder three steps height. Standard configure: temperature controller, storage battery, oxygen cylinders (2pcs), infant bed, skin temperature sensor, I.V. Pole, air filter, observation lamp, air cushion stand, power cord(AC or DC). Technical specification: Power supply: AC110V~230V, 50HZ/60 HZ DC power: DC12V or DC24V Power input:  ≤200VA Air Temperature control range: 25℃~37℃ Skin Temperature control range: 34℃~37℃ Sensor precision:   ≤0.3℃ Uniformity of bed temperature: ≤1.5℃ (bed is on level position) Temperature rising time:  ≤30min (environmental temperature  ≤50dB) Technical specification of storage battery: Type: Topin TP12-26 (12V26AH/20HR) Quantity: 1 sets(you can also choose 2 sets) Power supply: 12V/26AH Charging time: (complete disging state): 10 hours (1pc of storage battery) life time: complete gingdisging in 200 times Continue working time (environmental temperature 15℃, control temperature 36℃): 90min (1pc of storage battery) Alarming: audible visible alarm indication, it can indicate the real temperature cut off the power supply of heater (except for the low voltage), meanwhile, the skin temperature indication window can indicate the alarm code. For the alarm 1-6, the relevant light is on, for the alarm 7, all alarming lights are on; all alarm sound can be cancelled except for the power failure alarm the system alarm. Over-temp alarm: when the temperature ≤40℃; Deviation alarm: air temperature control ±3℃, the skin temperature control ±1℃; Sensor alarm: when the sensor is disconnected, open circuit, short circuit or put on the wrong place; Fan alarm: when the fan is disconnected, blocked, or stop working; Power failure alarm: when the storage battery is failed the power cord is disconnected. Low voltage alarm: DC power 12V, output <10.5V, DC power 24V, output <22.5V System alarm: when there is E2ROM malfunction inside of temperature controller.